It is possible to set the position difference between the positioning encoder and a redundant encoder. In this, parameter
P 0524 is used to set the channel of the redundant position encoder and parameter
P 0597 specifies the maximum position difference in increments. Monitoring is not active if P 0524 = 0 and the drive has been referenced. It is reset when the associated error is acknowledged or homing is executed again.
Parameters
P. no. |
Parameter name/ Setting |
Function |
---|---|---|
P 0524 | ENC_EncRedPos | Selection of the channel (1-3) with which the position encoder is to be evaluated. |
P 0597 | ENC_RedPos_DiffMax | Setting of the maximum position difference in increments. |
Tabelle: Monitoring the position difference